Home / Articles / Carotid duplex
Carotid duplex by voice: CCA, ICA, vertebral arteries and IMT in a Word and PDF report
Carotid duplex is two mirrored sets of vessels and many velocities. Mixing up a side or CCA with ICA while typing is easy. Dictate by side and the service assigns the vessels and calculates the velocity ratio.
Who it is for
Sonographers and vascular specialists, neurologists with duplex in the office, anyone following atherosclerosis and stented patients. The package: right and left sides with CCA, ICA, vertebral artery, IMT, velocities, stenoses, 24 parameters.
Sign up in a minute
- Open the app or the web cabinet and enter your email. No password: you get a code and a sign-in link.
- Signing in is the registration. Free minutes are credited at the start, no card needed.
- Fill the directories once: physician, workplace, scanner. They go into every report.
How to pick this exam type
Pick Carotid duplex. Velocities in cm/s, diameters and IMT in millimetres, stenoses in percent.
How to dictate
Right: CCA diameter, IMT, velocity; ICA diameter, velocity, stenosis; vertebral artery diameter, velocity. Then left and the same order. Describe plaques with location, structure and percent stenosis.
What to watch
- The ICA to CCA ratio is calculated from peak velocities for each side.
- Say the stenosis as a number with the word percent, it goes to its own field.
- IMT needs a decimal: zero point eight. The number 8 will not be placed into IMT.
- Describe a plaque in one phrase: location, structure, surface, stenosis.
What is calculated automatically
Calculated fields fill themselves when the inputs are dictated. Every formula shows its inputs.
- Right ICA/CCA PSV ratio = 0.8
ica_psv_r / cca_psv_r; ratio > 2 suggests ICA stenosis of 50% or more - Left ICA/CCA PSV ratio = 0.9
ica_psv_l / cca_psv_l; ratio > 2 suggests ICA stenosis of 50% or more
What the report will contain
Two side tables with identical rows, the calculated velocity ratio, reference ranges for diameters, IMT and velocities, plaque descriptions, impression.
Reference ranges are printed for information only: the service does not compare values with norms and does not write a diagnosis. The impression stays yours.
After processing
The result arrives in 20-40 seconds. Any value, label or unit can be corrected in the editor and formulas recalculate. The document opens in Word and PDF, prints from the browser with the patient name typed on the spot, and can be shared with a colleague by link.
Frequently asked questions
Which stenosis criteria are used?
The service grades nothing: you state the percent and the velocity ratio is plain arithmetic. Criteria stay with the physician.
Are subclavian arteries included?
The package focuses on CCA, ICA and vertebrals. Describe subclavians in a custom row in the editor.
Can I dictate the ECA?
Yes, the description goes to the side's text field. There are no separate numeric ECA fields.
How do I report tortuosity?
In words in the side's text field: C-shaped ICA tortuosity without hemodynamic significance.
Other exam types
- Echocardiography by voice: dictate the echo and get a finished report
- Abdominal ultrasound by voice: liver, gallbladder, pancreas and spleen report in a minute
- Kidney and bladder ultrasound by voice: sizes, parenchyma and residual urine in the report
- Thyroid ultrasound by voice: lobe volumes by Brunn and a report in Word and PDF
- Breast ultrasound by voice: BI-RADS per breast in a Word and PDF report
- Pelvic ultrasound by voice: uterine and ovarian volumes calculated, report in Word and PDF
- Prostate ultrasound by voice: gland volume and residual urine in a Word and PDF report
- Lower limb venous duplex by voice: compressibility, reflux and junctions in a Word and PDF report
- Soft tissue and lymph node ultrasound by voice: lesion and node in a Word and PDF report
- First trimester ultrasound by voice: CRL, gestational age, NT and the screening report in Word and PDF
- Second and third trimester ultrasound by voice: biometry, Hadlock EFW and Doppler in Word and PDF
- Scrotal ultrasound by voice: testicular volume, varicocele and flow in a Word and PDF report
- Joint ultrasound by voice: knee, shoulder and ankle in one Word and PDF report
- Infant hip ultrasound by voice: alpha and beta angles, Graf type in a Word and PDF report
- Neonatal cranial ultrasound by voice: ventricles, interhemispheric fissure and RI in a Word and PDF report
- Lower limb arterial duplex by voice: velocities, waveforms, stenoses and ABI in Word and PDF
- Veterinary abdominal ultrasound by voice: a report for cats and dogs in Word and PDF
- Veterinary echocardiography by voice: M-mode, LA/Ao and weight normalized dimensions for dogs in Word and PDF
- Veterinary pregnancy ultrasound by voice: vesicles, CRL and fetal heart rate in Word and PDF